Shanghai fly test aflatoxin B1 fluorescence quantitative rapid test strip (for feed)

[Aflatoxin B1 rapid quantitative fluorescence profile test strip]

      Aflatoxin B1 Fluorescent Quantitative Rapid Test Strip Based on the leading fluorescence quantitative FPOCT rapid detection technology platform, fluorescent nanospheres are used to label specific aflatoxin monoclonal antibodies by lateral immunochromatography (Fluorescent Lateral Flow, FLF), which can quickly and accurately quantify the content of aflatoxins in various simple and complex samples within 8 min. It has high sensitivity, wide linear range, high accuracy, good precision, wide application range, easy and fast operation. Etc.

Fluorescence quantitative rapid detection test strip principle of aflatoxin

[Aflatoxin B1 Fluorescence Quantitative Rapid Test Strips Scope]

This product is suitable for rapid quantitative detection of feed ingredients (such as rice, corn, wheat, barley, sorghum, soybean meal, corn bran, peanut meal, bran, DDGS, etc.) and residual concentration of aflatoxin B1 in feed products, sample pretreatment Simple, the whole testing process only takes about 15 minutes (pre-treatment 7min + detection 8min), suitable for all kinds of feed processing enterprises, breeding enterprises, third-party testing institutions and government supervision departments at all levels.

[Aflatoxin B1 Fluorescence Quantitative Rapid Test Strip Product Performance Parameters]

Aflatoxin rapid detection card parameters

[Aflatoxin B1 Fluorescence Quantitative Rapid Test Strip Sample Pretreatment Process]

1, crushing, weighing;

2. Add sample extract to extract (5min);

3. Centrifugation;

Aflatoxin rapid detection pretreatment

[Aflatoxin B1 Fluorescence Quantitative Rapid Test Strip Detection Process]

1, diluted

2, sample loading, reaction (8min);

3, reading, print test report;

Aflatoxin rapid detection process

[Aflatoxin B1 Fluorescence Quantitative Rapid Test Strip Results Judgment and Output]

1. The quantitative test result will be displayed on the liquid crystal display of the fluorescence reader. At the same time, the paper test report can be obtained by pressing the print button. In addition, after the WIFI data upload function of the instrument is turned on, the test related data information will be automatically uploaded to the “food”. Secure traceability management cloud platform for easy traceability and quality management.

Aflatoxin rapid detector