Sterilizer application range and function parameters

The sterilizer releases a high-energy radio frequency electric field during operation, changes the living environment of bacteria and algae cells, causes them to lose their living conditions and dies, thereby having the function of sterilization and algae elimination. The cell membrane has many externally associated ion channels, and the regulation of ion channels directly affects the function and life of the cells. The external electric field generated by the sterilizer destroys the ion channel on the cell membrane, changes the internal control current that regulates cell function, and affects the life of the bacteria. At the same time, the high-speed moving electrons generated by the radio frequency electric field of the sterilizer will kill the cells and achieve the purpose of sterilization. During the electric field treatment of water, dissolved oxygen is activated, superoxide anion radicals, hydroxyl radicals, hydrogen peroxide, singlet oxygen and other active oxygen. Active oxygen oxidizes the microbial organism, causing aging and death of the organism. For systems with high intelligence requirements, “Intelligent Sterilizer” can be used. “Intelligent Sterilizer” is a comprehensive water quality detection instrument based on the common “sterilization instrument”. When water quality is concentrated and deteriorated, When the standard is exceeded, an audible and visual alarm can be realized.

Application range of sterilizer Anti-scaling, anti-corrosion, anti-corrosion, sterilization and algae elimination in many fields such as tap water, chilled water, cooling water, heating water, bath water, ground water, swimming pool water, industrial water, etc.
Technical characteristics of sterilizer Electromechanical integration design, small volume, large flow, pure physical treatment, no pollution to water quality, low operating and management costs, simple operation and convenient maintenance.

Sterilizer function parameters

Sterilizer adapts to water quality: total hardness ≤700mg/l (CaCO3)
Sterilizer control corrosion rate ≤0.092 mm / year anti-scaling and descaling efficiency ≥95% bactericidal algae ≥97%
Sterilizer pressure loss: ≤ 0.02MPa
Sterilizer working power: 190 ~ 250V 50 ~ 60Hz
Sterilizer safety insulation voltage: 5000V
Sterilizer working environment requirements: -25 ° C ~ +50 ° C relative humidity ≤ 95%
Sterilizer working medium temperature: -25 ° C ~ +90 ° C Power consumption: ≤ 340W
Mean time between failures of the sterilizer: no less than 50,000 hours