Introduction of condom packaging integrity test methods and testing instruments

Condom package integrity is an important quality assessment method for detecting condom packaging to ensure lubricant leakage. This test is critical because the condom package itself has a gap that makes it more likely to leak lubricant. As an excellent provider of international testing instruments and testing services, Labthink combines professional testing instruments to introduce the condom packaging integrity test method for the relevant units to understand the condom packaging integrity testing technology.
1, the implementation of standards
GB 7544-2004, ISO 4074:2002 "Technical requirements and test methods for natural latex rubber condoms"
2, instruments and requirements
The MFY-01 seal tester, in which the vacuum tank (vacuum tank) can withstand an atmospheric pressure difference, can observe the inside of the tank during the test. Vacuum pump is used to directly vacuum the vacuum tank according to the standard requirements. This test method will affect the precise control of the vacuum degree due to the pulsation generated when the vacuum pump works, and thus it is easy to cause misjudgment. Labthink's MFY-01 Sealing Tester uses a vacuum converter to create a smooth vacuum in the vacuum tank, ensuring the accuracy of the equipment. It is a high-precision instrument for testing the complete performance of condoms without the need for a vacuum pump. It is necessary to connect the pressure source of the factory or laboratory.
3, the principle of condom package integrity test
By vacuuming the vacuum chamber, the sample immersed in water (the dye is filled with dye) is subjected to internal and external pressure difference, and the gas escape in the sample is observed to determine the sealing performance of the sample; The vacuum is used to make the sample have a pressure difference between the inside and the outside, and the sample is inflated after the sample is expanded and the vacuum is released, thereby determining the sealing performance of the sample. The following is a schematic diagram of the test principle:

4, condom packaging integrity test method
Water is filled into the vacuum tank (filling with dye), and the individual packaged condom is immersed in the vacuum tank, and the upper pressure plate is covered, and the condom is required to be 25 mm from the water surface. Set the absolute pressure of the vacuum tank to 20±5 kPa, and set the vacuum holding time to 1 min. Start the test. When the vacuum is increased, observe the condom package to form the form of continuous bubbles to characterize the leakage. Note that the bubbles that appear independently cannot be confirmed. For leakage, after 1 min of maintenance, if no continuous bubbles are generated, uncover the lid and check if the condom package is inside to further confirm the presence or absence of leakage.
5, the results of the assessment
1) If the continuous bubble is generated during the vacuum increase or the vacuum holding period within the specified time, the leak is present and the sample is unqualified.
2) If the test liquid appears in the package at the end of the test, it is a non-conforming product.
3) If no continuous bubbles appear and no test liquid is found in the package, the package is acceptable.

Cilastatin

Cilastatin Acid,Imipenem Cilastatin,Cilastatin Intermediate,Imipenem Cilastatin Cost

Xinxiang Haibin Pharmaceutical Co.,Ltd , https://www.carbapenemspharmacy.com