How to install a pipeline centrifugal pump

How to install a pipeline centrifugal pump:

1. When the elevation and water temperature of the installation place of the pipeline centrifugal pump are different from the test conditions, if the local altitude is more than 300 meters or the water temperature of the pumped water exceeds 20 degrees Celsius, the calculated value should be corrected. That is, the atmospheric pressure at different elevations and the saturated vapor pressure above 20 degrees Celsius. However, when the water temperature is below 20 degrees Celsius, the saturated vapor pressure is negligible.

2. From the pipeline installation technology, the suction pipe requires strict sealing, and it cannot leak or leak water. Otherwise, the vacuum at the water inlet of the pump will be destroyed, so that the water output of the pump will be reduced, and even if it is serious, the water will not be pumped. Therefore, it is necessary to carefully do the interface work of the pipeline to ensure the construction quality of the pipeline connection.

3. The key to the installation technology of the pipeline centrifugal pump is to determine the installation height of the pump (ie suction stroke). This height refers to the vertical distance from the water source to the centerline of the pump impeller. It is not to be confused with the allowable vacuum height. The allowable vacuum height indicated on the pump product specification or on the nameplate refers to the vacuum value on the pump inlet section. The test was carried out under the conditions of 1 standard atmospheric pressure and a water temperature of 20 degrees Celsius. It does not take into account the flow of water after the suction pipe is fitted. The installation height of the pump should be the value of the remaining part that allows the suction vacuum height to be deducted from the loss of the suction pipe. It must overcome the actual terrain water absorption height. The installation height of the pump should not exceed the calculated value. Otherwise, the pump will not be able to pump water or cavitation.

4. The magnitude of the influence calculation value is the resistance loss head of the suction pipe. Therefore, it is advisable to use the short piping arrangement of the Zui, and to install the fittings such as elbows as little as possible. It is also conceivable to properly fit the water pipes with a larger diameter to reduce the flow velocity inside the pipe.

Installation method of pipeline centrifugal pump:

Polydextrose

FUNCTION

Increase the volume of feces, enhance bowel movement, reduce the risk of intestinal cancer, etc. , combined with the removal of bile acids in vivo, lower serum cholesterol significantly, cause the feeling of satiety easily, can significantly reduce blood glucose levels after meal.

PHYSICAL PROPERTIES
1. Can replace sugar and fat in food and improve food texture and taste
2. Taste fresh, easy to release the food flavor. In various applications, have the function of improving the food flavor
3. Widely recognized as a good source of dietary fiber
4. Prebiotics which can improve the digestive tract health
5. Low blood glucose response, metabolism does not need insulin, suitable for diabetic patients
6. Satiety, help control body weight, apply to consumers who want to control the carbohydrate intake.
7. Good toleration.
Because of its low heat, stability, high tolerance characteristics, can be widely used in a variety of food, especially in low-energy, high fiber and other functional foods.

Polydextrose Powder

Polydextrose,dietary fiber, fiber

Shandong Bailong Chuangyuan Bio-tec Co.,Ltd , https://www.Chinabailong.com