Model NO.: YSD9800D
Payment: T/T , Wester Union
Cassette Image Receptor: 18×24cm
Power Rating: 6kw
Weight: 340kgs
Cbm: 2.15 M3
Focal Spot: Dual Focus 0.2 / 0.4mm
Focal: Small Focal Point 20-35kv/10-100mas
Trademark: YSD
Transport Package: in Carton Packing
Specification: 940mm*560mm*2000mm
Origin: Chengdu, China
HS Code: 9022140090
YSD9800D High Frequency Mammography  UnitApplication:
Mammography Unit is a X-ray apparatus involving in various advanced technologies, specially designed for the diagnosis of mammary gland diseases. It is sensitive to mammary gland lump, calcification, protuberance and carcinogensis and first-choice apparatus for the image examination of mammary diseases in medical institutes.
Â
Main Parameters:
(IAE C339V tube)
1. Â X-ray Generator
   Complete solid-state high-frequency high-voltage generator.
   Generator Type: High Frequency Inverter 80kHz
   Input Power: Single phase 220VAC, 50/60Hz
   Radiographic Ratings: Large Focal Point 20-35kV/10-510mAs
                    Small Focal Point 20-35kV/10-100mAs
   Power Rating: 6.2kW
Â
2. Â X-ray Tube
   Model: IAE C339V
   Focal Spot Size: Dual Focus 0.1/0.3mm
   Target Material: Molybdenum (Mo)
   Port Material: Beryllium (Be)
   High-speed anode drive: 2800/1000rpm
   Target angle: 10°/16°
   Anode Heat Storage: 210kJ (300kHU)
   Anode Cooling: Air cooling
   Filtration: Mo(0.03mm),Al(0.5mm)
3. Â Radiographic Stand
   C-ARM: Vertical Movement: 590mm
   Center of electric rotating C-arm, automatic return function by one key
   Automatically released after the exposure pressure settings display
   Compression flexible stepless speed.
   Max. pressure: 200N
   Max. travel: 150mm
   Rotations Deg:+90°~-90°
   SID: 650mm
Â
4. Â Cassette Image Receptor
   18*24cm (24cm*30cm optional)
   Bucky Device: 18*24cm Bucky drive mechanism,(24cm*30cm optional)
   Grid Ratio: 5:1, 30 Line/cm
Â
5. Â Line Voltage
   220Vac@25A, Single phase
Â
6. Â Weight and Size:
   240kg(Gross weight: 340kg)
   L*W×H: 940mm*560mm*2000mm
Â
Â
Upgrading:
Above introduction for YSD9800D is an analog mammography, actually, it can be upgraded into a DR system. Here is the main parameters for digital mammography.
Â
Main Parameters for Full Digital Mammography System | ||
Name | Parameters | |
Specialized Digital Flat Panel Detector for Mammography | Detector, Power Box, Date Line, Capture Card, etc | |
Effective Coverage of Detector | 23*15cm, 29*23cm | |
Pixel Matrix | 3072*1944, 3888*3072 | |
Limit of Spatial Resolution | 6.0Lp/mm | |
DQE Value | 70% | |
Dynamic Range | 14bit digital output | |
Pixel Size | 75um | |
High Voltage Synchronizer | BNC | |
Output | Camera Link or Ethernet | |
Working Condition | 10-40ºC | |
Storage Environment | -10-50ºC | |
Bucky | Housing and Movement Device | |
Size | 370*275*125cm | |
Stepless Speed Regulating Range | 0-6cm/s | |
Movement Range | 0.5-2cm | |
Grid | ||
Size | 24*30cm | |
Grid Ratio | 3.5:1 | |
Focal Distance | 65cm | |
Software | ||
Workstation | Standard Detector Image Acquisition Workstation | |
CPU≥Intel Duo Core 2.60GHz | ||
Hardware≥250G | ||
Memory≥2G | ||
Display Card≥512MB | ||
19'' High Brightness High Contrast LCD, 1280*1024 Pixel Resolution | ||
Network Interface Worklist | ||
DICOM3.0 Transmission | ||
100/1000 Gigabit Ethernet |
Why choose us:
We got production and business certification from Chengdu food and Drug Administration
We got business license from Chengdu City Administration of industry and commerce
We got products certificate of registration and have checked in the website of SFDA
We have accepted the onsite check from SFDA every quarter
We finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;
Our Certificates:
Â
Intraoral Cameras,Dental Camera,Dental Intraoral Camera
Dental Equipment Co., Ltd. , http://www.sofine-dental.com